ambient temperature up to 90°C requires customer supplied circulating bath
without thermo-circulating fittings
REFLEX Analytical offers two different solids cell holders for use with the Transmission Cell Heating Jacket. Part number 20600 has a fixed size aperture of 10mm and hence solid samples can be analyzed from 12mm to 28mm diameter and up to 3mm thick. Part number 20610 consists of outer and inner cell threaded bodies and three pairs of pressure plates. The varying aperture sizes of the pressure plates enable samples with a diameter of 12 - 17mm, 17 - 22mm and 22 - 30mm and up to 8mm thick to be analyzed. A K-type NiCr/NiAl or T-type Cu/CuNi thermocouple can be inserted in the cell's thermocouple port to monitor sample temperatures. The solids cell holders can operate without transmission windows if desired. Select part number when ordering.
REFLEX Analytical offers sealed and demountable liquid cells for use with the Transmission Cell Heating Jacket.
Each version is supplied as a completely assembled cell with windows and a spacer at the pathlength of your choice. Sealed cells have a lead spacer and lead top gasket and all components are permanently amalgamated together. Demountable cells have a teflon spacer and teflon top gasket and as such allow for windows and spacer pathlengths to be interchangeable.
Each static version stainless steel cell assembly provides for a 25 x 10mm clear aperture and includes a front plate with inlet/outlet plugs and thermocouple port, a back plate, front gasket, rear gasket, threaded luer fitting, flushing tube, syringe needle, (2) teflon washers, a 3/23" Allen key, lead or teflon spacer (specify 0.025mm, 0.05mm, 0.1mm, 0.2mm, 0.5mm or 1.0mm) and a choice of transmission window materials. The transmission materials available include but are not limited to NaCl Sodium Chloride, KBr Potassium Bromide, CaF2 Calcium Fluoride, BaF2 Barium Fluoride, and ZnSe Zinc Selenide. A K-type NiCr/NiAl or T-type Cu/CuNi thermocouple can be inserted in the cell's thermocouple port to monitor sample temperatures.
Optional flow through cells have an alternative front plate with 1/16" o.d. stainless steel tubing brazed to the
sample port positions. The flow tubes are assembled with Swagelok connection fittings such that other liquid
delivery type tubing can be connected to the cell front plate. It is recommended that this flow kit plate is supplied attached to the sealed cells. In this fashion, the flow plate is sealed to the front lead gasket and sealed window assembly. The threaded luer and flushing tube cannot be attached to the flow cell front plate.
Contact REFLEX Analytical to discuss your application and requirement for either a sealed, demountable or flow through type cell.
select window material & pathlength
(assembled with Lead spacer)
select window material & pathlength
(supplied with Mylar or PTFE spacer)
select window material, sold as a pair
select window material & pathlength
select window material & pathlength
2000 psi and 5000 psi high pressure options. The useful temperature range from -15°C to 180°C. Assembled with two 1/16” Stainless Steel flow tubes. Fixed pathlengths include 0.5, 1.0, 2.0, 5.0 or 10mm. Available optical materials include Sapphire, Zinc Selenide and UV Quartz.
select material & pathlength. request quotation.
select material & pathlength. request quotation.
select material & pathlength. request quotation.
select material & pathlength. request quotation.
T-type Cu/CuNi Thermocouple
(customer supplied temperature monitor)