5 - 130°C Cuvette and Vial Transmission Analyzer

5 - 130°C Cuvette and Vial Transmission Analyzer
The Cuvette and Vial Transmission Analyzer is a precision engineered, high throughput accessory for quantitative and qualitative analysis of liquid samples in the UV-Vis-NIR spectral region. Individual samples holders are designed to accommodate standard 10mm pathlength cuvettes as well as 5, 8, and 12mm glass vials. Each holder is pin-positioned to ensure accurate alignment and maximum reproducibility. Click on the above image for an enlarged impression. Scroll below for order details.

The temperature range of the accessory is from 5 to 130°C with +/- 0.50% accuracy. Heating and cooling is controlled with a built-in Peltier device. The Peltier element provides for reproducible ramping and for reaching target temperatures quickly and reliably at 10°C/minute. The Peltier device must be water-cooled for proper operation which can be achieved by running cold tap water through the water jacket integrated into the accessory shell or by the use of an available external liquid circulator (scroll below). The system is driven by a digital temperature controller either directly or via PC with optional software control. The software allows for easily programmed temperature profiles with unlimited ramps and unattended automatic data collection with most instrument software platforms.

The Cuvette and Vial Transmission Analyzer will fit into most NIR spectrometers including the Thermo iS5 and PerkinElmer Spectrum Two. For UV-Vis spectrophotometers, it will fit the larger Cary and Lambda spectrometers. Contact REFLEX Analytical to discuss interfacing with your instrument.

Send This Page to a Colleague
UV-Vis Cuvette and Vial Analyzer
The Cuvette and Vial Transmission Analyzer is a precision engineered, high throughput accessory for quantitative and qualitative analysis of liquid samples in the UV-Vis-NIR spectral region. Individual samples holders are designed to accommodate standard 10mm pathlength cuvettes as well as 5, 8, and 12mm glass vials.

The temperature range of the accessory is from 5 to 130°C with +/- 0.50% accuracy. Heating and cooling is controlled with a built-in Peltier device.

The UV-Vis Cuvette and Vial Analyzer includes temperature controlled base. Select a sample holder and temperature controller.
$4,595.00
110-60XXX
NIR Cuvette and Vial Analyzer
The Cuvette and Vial Transmission Analyzer is a precision engineered, high throughput accessory for quantitative and qualitative analysis of liquid samples in the Near IR spectral region. Individual samples holders are designed to accommodate standard 10mm pathlength cuvettes as well as 5, 8, and 12mm glass vials.

The temperature range of the accessory is from 5 to 130°C with +/- 0.50% accuracy. Heating and cooling is controlled with a built-in Peltier device.

The UV-Vis Cuvette and Vial Analyzer includes temperature controlled base. Select a sample holder and temperature controller.
$3,795.00
110-60XX
Digital Temperature Control Module
UV-Vis-NIR Cuvette and Vial Analyzers Digital Temperature Control Module.

Temperature Range: 5 to 130°C with +/- 0.50% accuracy.
$2,795.00
076-1510
10mm Pathlength Cuvette Holder
$175.00
111-3640
Glass Vial Holders
$205.00
111-36XX
VialSize: 
Glass Cuvette 10mm Pathlength
Standard cuvette with fitted cover. Satin finish on two sides. Dimensions 45mm height x 12.50mm wide.

Application: Visible

Material: Glass

Standard Pathlength: 10mm

CLICK HERE to download the Cuvettes and Cells Catalog to preview pathlength, cell dimensions and cell volume.

Percentage Transmission: > 82% @ 350nm

CLICK HERE to download the transmission performance curves for UV Quartz, IR Quartz and glass materials.
$45.00
T1G-10
Glass Vials
sold as a package of 200 vials

Application: Visible

Material: Glass

Standard Vial Sizes: 5mm 8mm 12mm

Percentage Transmission: > 82% @ 350nm

CLICK HERE to download the transmission performance curves for UV Quartz, IR Quartz and glass materials.
$130.00
162-02XX
Size: 
UV Quartz Cuvette 10mm Pathlength
Standard cuvette with fitted cover. Satin finish on two sides. Dimensions 45mm height x 12.50mm wide.

Application: UV-Vis

Material: UV Quartz

Standard Pathlength: 10mm

CLICK HERE to download the Cuvettes and Cells Catalog to preview pathlength, cell dimensions and cell volume.

Percentage Transmission: > 80% @ 200nm

CLICK HERE to download the transmission performance curves for UV Quartz, IR Quartz and glass materials.
$79.00
T1Q-10
IR Quartz Cuvette 10mm Pathlength
Standard cuvette with fitted cover. Satin finish on two sides. Dimensions 45mm height x 12.50mm wide.

Application: UV-Vis-NIR

Material: IR Quartz

Standard Pathlength: 10mm

CLICK HERE to download the Cuvettes and Cells Catalog to preview pathlength, cell dimensions and cell volume.

Percentage Transmission: > 82% @ 2730nm

CLICK HERE to download the transmission performance curves for UV Quartz, IR Quartz and glass materials.
$99.00
T1I-10
More Cuvette Options
Available with fitted covers, plugs, screw caps, anaerobic screw caps and graded seals. CLICK HERE for selection and ordering.

Application: UV-Vis-NIR

Materials: Glass, UV Quartz and IR Quartz

CLICK HERE to download the Cuvettes and Cells Catalog to preview pathlength, cell dimensions and cell volume.

CLICK HERE to download the transmission performance curves for UV Quartz, IR Quartz and glass materials.
Liquid Recirculator
Liquid Recirculator

WATER COOLING: Peltier device must be water-cooled for proper operation. This is achieved by running cold tap water through the water jacket integrated into the accessory shell, or by the use of an external liquid circulator as pictured.
$1,195.00
170-1100