-190 to 250°C Liquid, Solid, Gas Cell

-190 to 250°C Liquid, Solid, Gas Cell
-190 to 250°C Liquid, Solid, Gas Transmission Cell

This is a -190 to 250°C Variable Temperature Cell which permits transmission mode measurement of solid and liquid samples with gas exchange capabilities across the face of a solid sample. The cell consists of a vacuum outer jacket and a cold finger that may be cooled with liquid refrigerant. Sample cells are inserted into a block attached to the cold finger fitted with heaters to maintain precise temperature control. The external vacuum jacket windows are heated to prevent condensation at sub-ambient temperatures. The sealed or demountable liquid cell asssembly can be converted to a flow cell configuration with the appropriate attachment. Two fixed thermocouples are installed to monitor the temperature of the cell holder and the outer jacket window assembly. A spare thermocouple can be introduced to accurately monitor the sample temperature. The cell can be configured for UV-Vis and Fluorescence applications.

Options available include liquid sealed and demountable cell configurations, solids cell, flow through cells, and a variety of window materials to assemble within these cells. Scroll below for impression and order details.

High pressure cells are available for liquid and gas samples analysis under high pressure (2000 psi and 5000 psi options). The useful temperature range for the high pressure cells is from -15°C to 180°C. The cells are fabricated from Stainless Steel for chemical resistance and durability with two 1/16” Stainless Steel flow tubes brazed to the cell body. A choice of fixed pathlengths include 0.5, 1.0, 2.0, 5.0 or 10mm. The transmission windows are permanently sealed in the cell housing using perfluoroelastomer o-rings. Available optical materials include UV Quartz, Sapphire and Zinc Selenide.

The high pressure cells can be used at ambient temperature when mounted on the standard 3" x 2" backplate. For heated or sub-ambient applications, the cells listed below can also be used with the 250°C Solid and Liquid Cell and the Transmission Cell Heating/Cooling Jacket.

Additional options represent a choice of temperature controllers for 110V or 220V operation with or without an RS-232, USB or RS-485 computer interface.

REFLEX Analytical welcomes your contact to discuss your application demands. CLICK HERE for the User Manual and to appreciate the precision design and engineering features.

You may refer to this Product DataSheet to assist with ordering the items below. Recall to specify your spectrometer make and model.

Send This Page to a Colleague
–190 to 250°C Variable Temperature Cell
two window port vacuum jacket with programmable temperature controller

(select window material, add liquid/solid holder)
$13,250.00
21525-X
Material: 
–190 to 250°C Variable Temperature Cell
four window port vacuum jacket with standard 10mm pathlength cuvette holder and programmable temperature controller, includes four UV Quartz windows for UV-Vis and Fluorescence applications

(add cuvette type)
$19,585.00
21530
Outer Jacket Replacement Windows
select window material, sold as a pair
$335.00
2080X
Matl: 
Outer Jacket Replacement Windows
sold as a pair (two windows)
$3,110.00
20898
Matl: 
Solids Cell Holder
REFLEX Analytical offers a solids cell holder for use with the Variable Temperature Cell. Part number 20610 consists of outer and inner cell threaded bodies and three pairs of pressure plates. The varying aperture sizes of the pressure plates enable samples with a diameter of 12 - 17mm, 17 - 22mm and 22 - 30mm and up to 8mm thick to be analyzed. A T-type Cu/CuNi thermocouple can be inserted in the cell's thermocouple port to monitor sample temperatures. The solids cell holder can operate without transmission windows if desired.
$400.00
20610
Liquid Transmission Cells for -190 to 250°C Liquid, Solid, Gas Transmission Cell
REFLEX Analytical offers sealed and demountable liquid cells for use with the 250C Solid & Liquid Cell. Each version is supplied as a completely assembled cell with windows and a spacer at the pathlength of your choice. Sealed cells have o-ring seals. Demountable cells have a teflon spacer and teflon top gasket and as such allow for windows and spacer pathlengths to be interchangeable.

Each static version stainless steel cell assembly provides for a 25 x 10mm clear aperture and includes a front plate with inlet/outlet plugs and thermocouple port, a back plate, front gasket, rear gasket, threaded luer fitting, flushing tube, syringe needle, (2) teflon washers, a 3/23" Allen key, lead or teflon spacer (specify 0.025mm, 0.05mm, 0.1mm, 0.2mm, 0.5mm or 1.0mm) and a choice of transmission window materials. The transmission materials available include but are not limited to NaCl Sodium Chloride, KBr Potassium Bromide, CaF2 Calcium Fluoride, BaF2 Barium Fluoride, and ZnSe Zinc Selenide. A K-type NiCr/NiAl or T-type Cu/CuNi thermocouple can be inserted in the cell's thermocouple port to monitor sample temperatures.

Optional flow through cells have an alternative front plate with 1/16" o.d. stainless steel tubing brazed to the sample port positions. The flow tubes are assembled with Swagelok connection fittings such that other liquid delivery type tubing can be connected to the cell front plate.

Contact REFLEX Analytical to discuss your application and requirement for either a sealed, demountable or flow through type cell.
Demountable Static Liquid Cell
select window material & pathlength

(supplied with Mylar or PTFE spacer)
$939.00
GS2051X
Matl:  Path: 
Demountable Cell Windows
select window material, sold as a pair
$469.00
GS2052X
Material: 
Demountable Flow Cell, 1/16” o.d. Tubing
select window material & pathlength
$1,692.00
GS2058X
Matl:  Path: 
Sealed Flow Cell, 1/16” o.d. Tubing
select window material & pathlength
$1,920.00
GS2059X
Matl:  Path: 
High Pressure Cells
2000 psi and 5000 psi high pressure options. The useful temperature range from -15°C to 180°C. Assembled with two 1/16” Stainless Steel flow tubes. Fixed pathlengths include 0.5, 1.0, 2.0, 5.0 or 10mm. Available optical materials include UV Quartz, Sapphire and Zinc Selenide.
2000psi High Pressure Liquid Cell, Pathlengths 0.5mm 1.0mm 2.0mm
select material & pathlength. request quotation.
5910-X
Matl:  Path: 
2000psi High Pressure Liquid Cell, Pathlengths 5mm 10mm
select material & pathlength. request quotation.
5920-X
Matl:  Path: 
5000psi High Pressure Liquid Cell, Pathlengths 0.5mm 1.0mm 2.0mm
select material & pathlength. request quotation.
5915-X
Matl:  Path: 
5000psi High Pressure Liquid Cell, Pathlengths 5mm 10mm
select material & pathlength. request quotation.
5925-X
Matl:  Path: 
Sample Monitoring Thermocouple
T-type Cu/CuNi Thermocouple

(customer supplied temperature monitor)
$320.00
GS20200