two window port vacuum jacket with programmable temperature controller (select window material, add liquid/solid holder) $13,250.00 | four window port vacuum jacket with standard 10mm pathlength cuvette holder and programmable temperature controller, includes four UV Quartz windows for UV-Vis and Fluorescence applications (add cuvette type) $19,585.00 |
select window material, sold as a pair $335.00 | sold as a pair (two windows) $3,110.00 |
REFLEX Analytical offers a solids cell holder for use with the Variable Temperature Cell. Part number 20610 consists of outer and inner cell threaded bodies and three pairs of pressure plates. The varying aperture sizes of the pressure plates enable samples with a diameter of 12 - 17mm, 17 - 22mm and 22 - 30mm and up to 8mm thick to be analyzed. A T-type Cu/CuNi thermocouple can be inserted in the cell's thermocouple port to monitor sample temperatures. The solids cell holder can operate without transmission windows if desired. $400.00 | REFLEX Analytical offers sealed and demountable liquid cells for use with the 250C Solid & Liquid Cell.
Each version is supplied as a completely assembled cell with windows and a spacer at the pathlength of your choice. Sealed cells have o-ring seals. Demountable cells have a teflon spacer and teflon top gasket and as such allow for windows and spacer pathlengths to be interchangeable. Each static version stainless steel cell assembly provides for a 25 x 10mm clear aperture and includes a front plate with inlet/outlet plugs and thermocouple port, a back plate, front gasket, rear gasket, threaded luer fitting, flushing tube, syringe needle, (2) teflon washers, a 3/23" Allen key, lead or teflon spacer (specify 0.025mm, 0.05mm, 0.1mm, 0.2mm, 0.5mm or 1.0mm) and a choice of transmission window materials. The transmission materials available include but are not limited to NaCl Sodium Chloride, KBr Potassium Bromide, CaF2 Calcium Fluoride, BaF2 Barium Fluoride, and ZnSe Zinc Selenide. A K-type NiCr/NiAl or T-type Cu/CuNi thermocouple can be inserted in the cell's thermocouple port to monitor sample temperatures. Optional flow through cells have an alternative front plate with 1/16" o.d. stainless steel tubing brazed to the sample port positions. The flow tubes are assembled with Swagelok connection fittings such that other liquid delivery type tubing can be connected to the cell front plate. Contact REFLEX Analytical to discuss your application and requirement for either a sealed, demountable or flow through type cell. |
select window material & pathlength (supplied with Mylar or PTFE spacer) $939.00 | select window material, sold as a pair $469.00 |
select window material & pathlength $1,692.00 | select window material & pathlength $1,920.00 |
2000 psi and 5000 psi high pressure options. The useful temperature range from -15°C to 180°C. Assembled with two 1/16” Stainless Steel flow tubes. Fixed pathlengths include 0.5, 1.0, 2.0, 5.0 or 10mm. Available optical materials include UV Quartz, Sapphire and Zinc Selenide. | select material & pathlength. request quotation. |
select material & pathlength. request quotation. | select material & pathlength. request quotation. |
select material & pathlength. request quotation. | T-type Cu/CuNi Thermocouple (customer supplied temperature monitor) $320.00 |